ITA ENG FRA ESP DEU POR
6-1622192 REV.14 30/07/2012 1/9
ARGO 1 - ARGO 2 SERIES
SWITCHBOARDS, PROGRAMMABLE FOR 1 OR 2 MOTORS
WITH INDEPENDENT SLOWDOWN CONTROL
1. Introduction.
IMPORTANT: DO NOT INSTALL THE SWITCHBOARD BEFORE READING THE INSTRUCTIONS!!!!
The Argo control unit is an apparatus fit to manage operation and control of 1 or 2 wing gates with 230V AC motors and power of up to 600W each.
The time functioning of the control unit, being of electronic type, is extremely precise. It is however possible that, due to the type of the motor
normally utilised, the corner of the travelling time of the wing is strongly influenced by the frictions that the wing self meets during the
course.
Consequently , also if the time is correctly set, the corner of the wings’ opening can not be always the same wished.
Therefore it is advisable that the installer considers it, increasing, if necessary, the times of work in the more consonant measure with
the installation and making anyway attention to the fact that an excessive increasing of the time could mask the slowing down in opening
and in closure (see paragraph 6).
For the correct functioning it is also necessary the installation of the mechanical stops in opening and in closure (see pag. 6).
2. Configuration.
3. Electrical connections.
Electrolock output
12 Vac 12W Max
Indicator of open gate
24 Vac 2W max.
Connector
transformer
Dip-switch
Fuse
Connector
radio
module
Trimmer of
regulation
Learning
button
Power supply
230 Vac 50 Hz.
Molex radio
module
Table of contents:
FOTO CH = Photocell closing
FOTO AP = Photocell opening
AP = open
CH = close
Com = Common
PP = step by step button
Ant = Antenna
PED = Pedestrian button
F.C. 1 = limit switch 1
F.C. 2 = limit switch 2
Any control or safety device de-
signed for acting as a Normally
Closed (N.C.) contact, must be
provided with a jumper, if not
used.
3 4 5 6 7 8 9 10 11 12
Motor 2 Motor 1
Photocells
power supply
(see par.7.6)
Flashing light 230 Vac 60W max
N.B.: Use flashing light B.RO LIGHT FIX.
(Without autoflashing circuit
)
Vue de la page 0
1 2 3 4 5 6 7 8 9

Résumé du contenu

Page 1 - ARGO 1 - ARGO 2 SERIES

ITA ENG FRA ESP DEU POR 6-1622192 REV.14 30/07/2012 1/9 ARGO 1 - ARGO 2 SERIES SWITCHBOARDS, PROGRAMMABLE FOR 1 OR 2 MOTORS WITH I

Page 2 - TRANSMITTER

ITA ENG FRA ESP DEU POR 6-1622192 REV.14 30/07/2012 2/9 SAFETY WARNINGS • Some points of the electrical card are under voltage. Th

Page 3

ITA ENG FRA ESP DEU POR 6-1622192 REV.14 30/07/2012 3/9 6. Regulation. By cutting the bridge indicated in the figure, it is possibl

Page 4

ITA ENG FRA ESP DEU POR 6-1622192 REV.14 30/07/2012 4/9 6.2 Torque adjusting of the motor. The control unit Is furnished with a tri

Page 5 - 7.6 Photocell test

ITA ENG FRA ESP DEU POR 6-1622192 REV.14 30/07/2012 5/9 7.4 Pre-blinking function. Pre-blinking function enabled. The gate motion i

Page 6 - Conceptual diagram of

ITA ENG FRA ESP DEU POR 6-1622192 REV.14 30/07/2012 6/9 FC 1 FC 2 FC 1 FC 2 An ta B An ta AEsemp io di funzio namento simmet

Page 7

ITA ENG FRA ESP DEU POR 6-1622192 REV.14 30/07/2012 7/9 8. Additional variations. 8.1 Water hammer timing change. If the water hamm

Page 8 - 1 2 3 1 2 3

ITA ENG FRA ESP DEU POR 6-1622192 REV.14 30/07/2012 8/9 Once performed movement gate regulation, it is possible that the point in w

Page 9

ITA ENG FRA ESP DEU POR 6-1622192 REV.14 30/07/2012 9/9 GUARANTEE: The producer’s guarantee is valid in compliance with the law, fr